Dual Output 57V 12V Open Frame 200W Constant Voltage Power Supply

         Constant Volatge Power Supply 200W dual output 57V 12V

Description:
100-240VAC input constant voltage switching power supply 200W open frame dual output 57V 12V,it is designed for one of our customers,at present it is widely used to the stage lights.


Features:
1, dual power supply 57V 12V is high efficiency, low temperature rise; 
2, open frame 200W power supply;
3, 200W switching power supply open with short circuit, overload, overvoltage protection.
Parameter
            Item NO
K18-UP200D5712L
Output
Output Voltage
CH1:+57VDC;      CH2:+12VDC
Rated Current
CH1:4A;                 CH2:1A
Current Range
CH1:4A(constant current);                 CH2:0-1A
Rated Power
240W
Ripple & Noise
CH1:800mVp-p;  CH2:250mVp-p
Adjustable Output Range
CH1:51.3-62.7V
Output Accuracy
CH1:±2%     CH2:+/-5%
Line Regulation
CH1:±2%     CH2:+/-2%
Load Regulation
CH1:±2%     CH2: +/-2%
Set up,Rise,Keep up time
300ms, 20ms, 12ms
Input
Input Voltage Range
88~264VAC 
Input Current
1.6A/115V,0.8A/230V
Input Frequency
47~63Hz
Efficiency
90%@230V
Power Factor
95%@230VAC,98%@115VAC
Inrush Current
Cool start 20A/230V
Leakage Current
<0.5mA@240V
Protection
Over Load Protection
105~180%,Hiccup protection,automatic recovery
Short Circuit Protection
Hiccup protection,automatic recevery.
Output over-voltage protection
>150% automatic recovery
Over-temperature protection
>105 ℃ protection, automatic recovery
Environment
Working Temp.,Humidity
-20~40℃,10~90% RH,No condensation
Storage Temp.,Humidity
-20~85℃,10~95% RH
Temp.,Drift
±0.03%/℃(0~50℃)
Vibration
10~500Hz, 2G 10min /1cycle,PERIOD FOR 60min EACH AXES
Safety&EMC Standards
Safety Standards
GB4706,EN60950-1
Withstand Voltage
I/P-O/P:3KV;I/P-FG:1.8KV;O/P-FG:0.06KV AC
Insulation Resistance
I/P-O/P,I/P-FG,O/P-FG:500VDC / 100M Ohms
EMC Standards
............
OthersDimension
127*82*40mm(L*W*H)
Weight0.4kg
MTBF
>50hrs
Fan SupplyYES
Notes
1. All parameters 230VAC input, rated load, ambient temperature 25 ℃, measured under conditions of 70% humidity;
2. Accuracy: includes set up tolerance, line regulation, load regulation and so on;
3. Ripple Test: 20cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end;
4. Line regulation: at rated load conditions, the input voltage changes from low to high measured;
5. Load regulation: the measured output load from 0 to 100% load change measured.

Product picture:
constant voltage power supply 200W

评论

此博客中的热门博文

Brother Refill Ink For DCP- T300/T500W/T700W,MFC-T800W

3BHE004573R0143 | ABB | INTERFACE BOARD

CM520-8B Dual Sim Card 4G Industrial Cellular Router