Dual +24VDC 2A -24VDC 1A Power Supply For Appliance Industry

The article from :Guangzhou Kaihui Electronics Co.,Ltd (https://www.gzkaihui.com/)
Dual +24VDC 2A -24VDC 1A Power Supply For Appliance Industry
Description:100-240VAC input dual 24V switching power supply,it is designed for one of our customers,at present it is widely used to the stage lights and home appliance.


Features:
1, dual power supply 24V is high efficiency, low temperature rise; 
2, 72W switching power supply;
3, Dual output power supply 24V with short circuit, overload, overvoltage protection.
Parameter
            Item NO
K05-U60D24
Output
Output Voltage
CH1:+24VDC;      CH2:-24VDC
Rated Current
CH1:2A;                 CH2:1A
Current Range
CH1:0.2-2.5A;        CH2:0.1-1A
Rated Power
72W
Ripple & Noise
CH1:240mVp-p;  CH2:240mVp-p
Adjustable Output Range
CH1:21.6-26.4V
Output Accuracy
CH1:±1%     CH2:+/-6%
Line Regulation
CH1:±0.5%     CH2:+/-2%
Load Regulation
CH1:±0.5%     CH2: +/-5%
Set up,Rise,Keep up time
500ms, 100ms, 30ms
Input
Input Voltage Range
88~264VAC,120-360VDC
Input Current
2.4A/115V,1.2A/230V
Input Frequency
47~63Hz
Efficiency
82%@230V
Power Factor
>0.5
Inrush Current
Cool start 30A/230V
Leakage Current
<0.5mA@240V
Protection
Over Load Protection
105~180%,Hiccup protection,automatic recovery
Short Circuit Protection
Hiccup protection,automatic recevery.
Output over-voltage protection
>150% automatic recovery
Over-temperature protection
>105 ℃ protection, automatic recovery
Environment
Working Temp.,Humidity
-20~60℃,10~90% RH,No condensation
Storage Temp.,Humidity
-20~85℃,10~95% RH
Temp.,Drift
±0.03%/℃(0~50℃)
Vibration
10~500Hz, 2G 10min /1cycle,PERIOD FOR 60min EACH AXES
Safety&EMC Standards
Safety Standards
GB4706,EN60950-1,EN55022 CLASSA
Withstand Voltage
I/P-O/P:1.5KV;I/P-FG:1.5KV;O/P-FG:0.06KV AC
Insulation Resistance
I/P-O/P,I/P-FG,O/P-FG:500VDC / 100M Ohms
EMC Standards
............
OthersDimension
110*78*35mm(L*W*H)
Weight0.35kg
MTBF
>50hrs
Fan SupplyNO
Notes
1. All parameters 230VAC input, rated load, ambient temperature 25 ℃, measured under conditions of 70% humidity;
2. Accuracy: includes set up tolerance, line regulation, load regulation and so on;
3. Ripple Test: 20cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end;
4. Line regulation: at rated load conditions, the input voltage changes from low to high measured;
5. Load regulation: the measured output load from 0 to 100% load change measured.

Product picture:
dual 24V switching power supply
dual power supply 57V 12V
open frame power supply 200W
constant voltage power supply 200W
Constant Voltage power supply 200W
57V 12V open frame 200W psu
200W constant voltage power supply

评论

此博客中的热门博文

Brother Refill Ink For DCP- T300/T500W/T700W,MFC-T800W

3BHE004573R0143 | ABB | INTERFACE BOARD

CM520-8B Dual Sim Card 4G Industrial Cellular Router