Dual +24VDC 2A -24VDC 1A Power Supply For Appliance Industry
The article from :Guangzhou Kaihui Electronics Co.,Ltd (https://www.gzkaihui.com/)
Dual +24VDC 2A -24VDC 1A Power Supply For Appliance Industry
Description:100-240VAC input dual 24V switching power supply,it is designed for one of our customers,at present it is widely used to the stage lights and home appliance.
 
 
 
 
 
 
 
Features:
1, dual power supply 24V is high efficiency, low temperature rise;
2, 72W switching power supply;
3, Dual output power supply 24V with short circuit, overload, overvoltage protection.
1, dual power supply 24V is high efficiency, low temperature rise;
2, 72W switching power supply;
3, Dual output power supply 24V with short circuit, overload, overvoltage protection.
| Parameter | |||||
| Item NO | 
K05-U60D24 | ||||
| Output | 
Output Voltage | CH1:+24VDC; CH2:-24VDC | |||
| 
Rated Current | CH1:2A; CH2:1A | ||||
| 
Current Range | CH1:0.2-2.5A; CH2:0.1-1A | ||||
| 
Rated Power | 72W | ||||
| 
Ripple & Noise | CH1:240mVp-p; CH2:240mVp-p | ||||
| 
Adjustable Output Range | 
CH1:21.6-26.4V | ||||
| 
Output Accuracy | 
CH1:±1%     CH2:+/-6% | ||||
| 
Line Regulation | 
CH1:±0.5%     CH2:+/-2% | ||||
| 
Load Regulation | 
CH1:±0.5%     CH2: +/-5% | ||||
| 
Set up,Rise,Keep up time | 
500ms, 100ms, 30ms | ||||
| Input | 
Input Voltage Range | 
88~264VAC,120-360VDC | |||
| 
Input Current | 
2.4A/115V,1.2A/230V | ||||
| 
Input Frequency | 
47~63Hz | ||||
| 
Efficiency | 
82%@230V | ||||
| Power Factor | 
>0.5 | ||||
| 
Inrush Current | Cool start 30A/230V | ||||
| 
Leakage Current | 
<0.5mA@240V | ||||
| Protection | 
Over Load Protection | 
105~180%,Hiccup protection,automatic recovery | |||
| 
Short Circuit Protection | 
Hiccup protection,automatic recevery. | ||||
| Output over-voltage protection | 
>150% automatic recovery | ||||
| 
Over-temperature protection | 
>105 ℃ protection, automatic recovery | ||||
| 
Environment | 
Working Temp.,Humidity | 
-20~60℃,10~90% RH,No condensation | |||
| 
Storage Temp.,Humidity | 
-20~85℃,10~95% RH | ||||
| 
Temp.,Drift | 
±0.03%/℃(0~50℃) | ||||
| 
Vibration | 
10~500Hz, 2G 10min /1cycle,PERIOD FOR 60min EACH AXES | ||||
| 
Safety&EMC Standards | 
Safety Standards | 
GB4706,EN60950-1,EN55022 CLASSA | |||
| 
Withstand Voltage | 
I/P-O/P:1.5KV;I/P-FG:1.5KV;O/P-FG:0.06KV AC | ||||
| 
Insulation Resistance | 
I/P-O/P,I/P-FG,O/P-FG:500VDC / 100M Ohms | ||||
| 
EMC Standards | 
............ | ||||
| Others | Dimension | 
110*78*35mm(L*W*H) | |||
| Weight | 0.35kg | ||||
| MTBF | 
>50hrs | ||||
| Fan Supply | NO | ||||
| Notes | 
1. All parameters 230VAC input, rated load, ambient temperature 25 ℃, measured under conditions of 70% humidity; 
2. Accuracy: includes set up tolerance, line regulation, load regulation and so on; 
3. Ripple Test: 20cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end; 
4. Line regulation: at rated load conditions, the input voltage changes from low to high measured; 
5. Load regulation: the measured output load from 0 to 100% load change measured. | ||||
Product picture:







评论
发表评论