ETL Certification 150W 24V 6.3A Switching Power Supply Single Output Open Frame
ETL certification 150W 24V 6.3A switching power supply single output open frame
Description:
K26H-UP150S series 150W 24V 6.3A switching power supply is 90-264Vac input voltage,less than 120W free air convection and 150W with 20CFM forced air,LED indicator for power on,we can provide 2 years warranty serve.
Features:
1, 150W high efficiency 24V switching power supply;
2, Built-in active PFC function power supply;
3, Wide range of AC input voltage,24V 150W single output power supply;
4, It have short circuit, over load, over voltage protection;
2, Built-in active PFC function power supply;
3, Wide range of AC input voltage,24V 150W single output power supply;
4, It have short circuit, over load, over voltage protection;
5, 150W 24V power supply used in LED light,stage light etc.
Parameter | |||||
Item NO | K26H-UP150S5 | K26H-UP150S12 | K26H-UP150S24 | K26H-UP150S36 | |
Output |
Output Voltage
| +5V | +12V | +24V | +36V |
Rated Current
| 20A | 12.5A | 6.3A | 4.2A | |
Current Range
| 0-20A | 0-12.5A | 0-6.3A | 0-4.2A | |
Rated Power(20CFM Fan) | 100W | 150W | 151.2W | 151.2W | |
Rated Power(Convection)
| <75W | <120W | <120W | <120W | |
Ripple & Noise
| 100mVp-p | 200mVp-p | 240mVp-p | 360mVp-p | |
Adjustable Output Range
|
±10%(5V:-5%~+10%)
| ||||
Output Accuracy
|
±1%
| ||||
Line Regulation
|
±0.5%
| ||||
Load Regulation
|
±0.5%
| ||||
Set up,Rise,Keep up time
|
500ms, 50ms, 20ms
| ||||
Input |
Input Voltage Range
|
90~264V AC
| |||
Input Current
|
0.8A@220V AC
| ||||
Input Frequency
|
47~63Hz
| ||||
Power Factor | >0.99@110V;>0.95@220V | ||||
Efficiency
| 80% | 85% | 87% | 87% | |
Inrush Current
| Cold start 20A@115V,40A@230V | ||||
Leakage Current
|
<1mA@240V
| ||||
Protection |
Over Load Protection
|
110~200%,Hiccup,automatic recovery
| |||
Short Circuit Protection
|
---
| ||||
Over Temp., protection | --- | ||||
Environment
|
Working Temp.,Humidity
|
-20~50℃,10~90% RH,No condensation
| |||
Storage Temp.,Humidity
|
-20~85℃,10~95% RH
| ||||
Temp.,Drift
|
±0.03%/℃(0~50℃)
| ||||
Vibration
|
10~500Hz, 2G 10min /1cycle, PERIOD FOR 60min EACH AXES
| ||||
Safety&EMC Standards
|
Safety Standards
|
EN60950-1
| |||
Withstand Voltage
|
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
| ||||
Insulation Resistance
|
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
| ||||
EMC Standards
|
EN55022 CLASS A EN61000-3-2
| ||||
Others | Dimension |
115*59*35mm(L*W*H)
| |||
Weight | 0.5kg | ||||
Notes |
1. All parameters 230VAC input, rated load, ambient temperature 25 ℃, measured under conditions of 70% humidity;
2. Accuracy: includes set up tolerance, line regulation, load regulation and so on;
3. Ripple Test: 30cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end;
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives;
5. Derating may be needed under low input voltages. Please check the derating curve for more details. |
Product picture:
评论
发表评论