PCB Type 60w Dual Output +12V/2.5A -12V/2.5A Smps Switching Power Supply From China Factory
Dual output 60W 12V -12V PCB Switching Power Supply
Description:
KPD60 Series can fulfill the requirements of general medical or industrial applications. 
Features:
1,60W DUAL Switching power supply 12V -12V with unversial AC input;
2, 60W SMPS with Short circuit, overload, overvoltage and over temperature protection;
2, 60W SMPS with Short circuit, overload, overvoltage and over temperature protection;
| 
SPECIFICATIONS | ||||||||||||
| 
  Item NO. | 
KPD60-0512 | 
KPD60-0524 | 
KPD60-1224 | 
KPD60-12 | ||||||||
| 
CH1 | 
CH2 | 
CH1 | 
CH2 | 
CH1 | 
CH2 | 
CH1 | 
CH2 | |||||
| 
OUTPUT | 
DC OUTPUT VOLTAGE | 
+5V | 
+12V | 
+5V | 
+24V | 
+12V | 
+24V | 
+12V | 
-12V | |||
| 
OUTPUT RATEDCURRENT | 
6A | 
2.5 | 
5A | 
1.5A | 
2A | 
1.5A | 
2.5A | 
2.5A | ||||
| 
OUTPUTCURRENT RANGE | 
0.1-6A | 
0.1-3A | 
0.1-6A | 
0.1-2A | 
0.1-2A | 
0.1-2A | 
0.1-3A | 
0.1-3A | ||||
| 
OUTPUT POWER | 
50W | 
61W | 
60W | 
60W | ||||||||
| 
RIPPLE & NOISE(p-p) | 
50mV | 
100mV | 
50mV | 
200mV | 
100mV | 
200mV | 
100mV | 
100mV | ||||
| 
VOLTAGE ADJ. | 
CH1:±10% (5V:4.75~5.5V) | |||||||||||
| 
OUTPUT V. TOLERANCE | 
±1% | 
±5% | 
±1% | 
±5% | 
±1% | 
±5% | 
±1% | 
±5% | ||||
| 
LINE REGULATION | 
±0.5% | 
±1% | 
±0.5% | 
±1% | 
±0.5% | 
±1% | 
±0.5% | 
±1% | ||||
| 
LOAD REGULATION | 
±0.5% | 
±4% | 
±0.5% | 
±4% | 
±0.5% | 
±4% | 
±0.5% | 
±4% | ||||
| 
SETUP,RISE,HOLD UP TIME | 
500ms,50ms,20ms | |||||||||||
| 
INPUT | 
INPUT VOLTAGE RANGE | 
90-264V AC | ||||||||||
| 
INPUT CURRENT | 
0.3A @ 220V AC | |||||||||||
| 
INPUT FREQUENCY | 
47-63 Hz | |||||||||||
| 
EFFICIENCY | 
80% | 
86% | 
88% | 
89% | 
89% | |||||||
| 
INRUSH CURRENT | 
Cold start15A/115V,30A/230V | |||||||||||
| 
LEAKAGE CURRENT | 
<0.3mA@240V AC | |||||||||||
| 
PRODECTION | 
OVERLOAD PROTECTION | 
110~200%,HICCUP RESET:AUTO RECOVER | ||||||||||
| 
OVER VOLTAGE PROTECTION | 
130~150% | |||||||||||
| 
FUNCTION | ||||||||||||
| 
ENVIROMENT | 
WORKING TEMP., HUMIDITY | 
-10~45℃ 100% LOAD,45~60℃ 60% LOAD,10~90% RH,No condensation | ||||||||||
| 
STORAGE TEMP., HUMIDITY | 
-20~85℃,10~95% RH | |||||||||||
| 
TEMP. COEFFICIENT | 
±0.03%/℃(0~50℃) | |||||||||||
| 
SAFETY&EMC | 
SAFETY STANDARDS | 
EN60950; GB4943; UL60950 | ||||||||||
| 
WITHSTAND VOLTAGE | 
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||||||
| 
ISOLATION RESISTANCE | 
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms | |||||||||||
| 
EMC STANDARDS | 
Meet FCC.PART15.CLASS B; EN55022 CLASS B | |||||||||||
| 
OTHER | 
DIMENSION | 
101.6*50.8*27mm | ||||||||||
| 
WEIGHT | 
0.3Kg | |||||||||||
| 
NOTE | 
1. ALL PARAMETERS ARE SPECIFIED AT 220VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT. 
2.TOLERANCE:INCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION. 
3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR. 
4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD. 
5.LOAD REGULATION IS MEASURED FROM 0% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD. | |||||||||||
Product picture:

FAQ
A1: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q2: Do you accept OEM/ODM for the switching power supply?
A2: Yes. we do.
Q3:How about the quality?
A3:We have the better professional and experienced engineers team and strict QA and QC system.Repair rate under 0.1%~0.2%
Q4:What is PFC?
A4:PFC stands for Power Factor Correction. The purpose of PFC is to improve the ratio of apparent power and real power. The power factor is only 0.5~0.7 in non-PFC models. In PFC models, the power factor can reach above 0.9. The calculation formulas are as below:
Apparent Power=Input Voltage x Input Current (VA)
Real Power= Input Voltage x Input Current x Power Factor (W) 