Battery charger switching power supply 1000W dual 48V 36V
1000W dual 48V 36V switching power supply
Description:
Dual 48V 36V power supply 1000W is suitable for use in telecommunications, networking, test and measurement, IT applications, general electronics, low profile systems, automation, POS, motor based machinery and non patient contact medical equipment.
Features:
1, Dual 48V 36V power supply with full range of AC input voltage;
2, 1000W power supply 48V 36V have short circuit, overload, overvoltage and over temperature protection;
2, 1000W power supply 48V 36V have short circuit, overload, overvoltage and over temperature protection;
3, 1000W 48V 36V DUAL output power supply built-in active filters,low output noise;
4,This 1000w smps has high efficiency and low output noise.
Parameter
| |||
Item NO.
|
K19H-UP1000D48+36
| ||
CH1
| |||
Output
|
Output voltage
|
+48V
| |
Rated current
|
15A
| ||
Current range
|
0-20A
| ||
Rated power
|
1000W
| ||
Ripple
|
600mVp-p
| ||
Output adjustable range
|
±5%
| ||
Output accurancy
|
±1%
| ||
Line regulation
|
±0.5%
| ||
Load regulation
|
±0.5%
| ||
Set-up,rise,hold up time
|
500ms, 30ms,5ms/115VAC 300ms, 30ms,10ms/230VAC
| ||
Input
|
Input voltage
|
88~264V AC
| |
Input current
|
12A/115V 6A/230V
| ||
Frequency
|
47~63Hz
| ||
Efficiency
|
92% @230V,88% @115V
| ||
Inrush current
|
40A@230V
| ||
Leakage current
|
<3.5mA@240V
| ||
Power factor
|
>0.9@220V,>0.95@110V
| ||
Protections
|
Overload protection
|
105~150% protection, automatic recovery
| |
Short circuit protection
|
Automatic recovery
| ||
Output overvoltage protection
|
55-62V
| ||
Over temperature protection
|
The case temperature is greater than 105 ° C, the output is off, and the recovery is automatic.
| ||
Other function
|
Auxiliary power supply
|
Provide 12V 0.2A auxiliary voltage output
| |
Standby function
|
At the RC terminal, add a high level,turn off the CH1 and CH2 outputs.
| ||
Environment
|
Working temperature, humidity
|
-20~+60℃,10~90% RH,No condensation
| |
Storage temperature, humidity
|
-40~85℃,10~95% RH
| ||
Temperature drift
|
±0.03%/℃(0~50℃)
| ||
vibration
|
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
| ||
Safety&EMC standards
|
Safety standard
|
GB4943
| |
Withstand voltage
|
I/P-O/P:3KV,I/P-FG:1.5KV;O/P-FG:0.5KV DC 1min.
| ||
Insulation resistance
|
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
| ||
EMC standard
|
EN55032 CLASS A,EN61000-3-2
| ||
Others
|
size
|
180*82*48mm
| |
weight
|
1.2Kg
| ||
Remarks
|
1. All parameters are measured at 220 V AC input, rated load, ambient temperature 25 ° C, humidity 70%
2. Accuracy: including setting error, line regulation, load regulation rate;
3. Ripple test: 30cm long wire with the power and load, load and 0.1u and 47u capacitance to 20MHz oscilloscope measured at the load side;
4. Line regulation: the rated load conditions, the input voltage changes from low to high measured;
5. Load regulation: Measured output is measured from 0% load to 100% load change.
|
Product picture:
评论
发表评论