High voltage 220VAC dual 24V 12V open frame power supply 150W
Dual 24V 12V power supply 150W
Description:
Features:
1, 150W power supply 24V 12V have short circuit, overload, overvoltage and over temperature protection;
2, 150W open frame DUAL output power supply built-in active filters,low output noise;
3,Open frame dual 24V 12V smps has high efficiency and low output noise.
Parameter | |||
Item NO. | K26S-H160D24+12 | ||
CH1 | CH2 | ||
Output | Output voltage | +24V | +12V |
Rated current | 6A | 1A | |
Current range | 0-6A | 0-1A | |
Rated power | 156W | ||
Ripple | 300mVp-p | 150mVp-p | |
Output adjustable range | / | / | |
Output accurancy | ±2% | ±4% | |
Line regulation | ±1% | ±1% | |
Load regulation | ±1% | ±3% | |
Set-up,rise,hold up time | 600ms, 50ms,12ms/230VAC | ||
Input | Input voltage | 200~240V AC | |
Input current | 1.7A/230V | ||
Frequency | 47~63Hz | ||
Efficiency | 92% @230V | ||
Inrush current | cold start 45A@230V | ||
Leakage current | <0.3mA@240V | ||
Power factor | ............... | ||
Protections | Overload protection | 105~200% protection, automatic recovery | |
Short circuit protection | Hiccup,automatic recovery after abnormal conditions are removed | ||
Output overvoltage protection | >120% automatic protection | ||
Over temperature protection | .......................... | ||
Other function | Auxiliary power supply | ............................ | |
Standby function | .............................. | ||
Environment | Working temperature, humidity | -20~+50℃,10~90% RH,No condensation | |
Storage temperature, humidity | -20~85℃,10~95% RH | ||
Temperature drift | ±0.03%/℃(0~50℃) | ||
vibration | 10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES | ||
Safety&EMC standards | Safety standard | GB4706.1,EN60950-1 | |
Withstand voltage | I/P-O/P:3KV,I/P-FG:1.5KV;O/P-FG:0.5KV DC 1min. | ||
Insulation resistance | I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms | ||
EMC standard | GB9254 B,EN55032(CISPR22)CLASS B | ||
Others | size | 115*60*28mm | |
weight | 0.23Kg | ||
Remarks | 1. All parameters are measured at 220 V AC input, rated load, ambient temperature 25 ° C, humidity 70% 2. Accuracy: including setting error, line regulation, load regulation rate; 3. Ripple test: 30cm long wire with the power and load, load and 0.1u and 47u capacitance to 20MHz oscilloscope measured at the load side; 4. Line regulation: the rated load conditions, the input voltage changes from low to high measured; 5. Load regulation: Measured output is measured from 0% load to 100% load change. |